Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.502
Filtrar
1.
Anal Chem ; 96(15): 6079-6088, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38563576

RESUMO

Metal ion homeostasis is imperative for normal functioning of the brain. Considering the close association between brain metal ions and various pathological processes in brain diseases, it becomes essential to track their dynamics in awake animals for accurate physiological insights. Although ion-selective microelectrodes (ISMEs) have demonstrated great advantage in recording ion signals in awake animals, their intrinsic potential drift impairs their accuracy in long-term in vivo analysis. This study addresses the challenge by integrating ISMEs with photoelectrochemical (PEC) sensing, presenting an excitation-detection separated PEC platform based on potential regulation of ISMEs. A flexible indium tin oxide (Flex-ITO) electrode, modified with MoS2 nanosheets and Au NPs, serves as the photoelectrode and is integrated with a micro-LED. The integrated photoelectrode is placed on the rat skull to remain unaffected by animal activity. The potential of ISME dependent on the concentration of target K+ serves as the modulator of the photocurrent signal of the photoelectrode. The proposed design allows deep brain detection while minimizing interference with neurons, thus enabling real-time monitoring of neurochemical signals in awake animals. It successfully monitors changes in extracellular K+ levels in the rat brain after exposure to PM2.5, presenting a valuable analytical tool for understanding the impact of environmental factors on the nervous system.


Assuntos
Técnicas Biossensoriais , Vigília , Animais , Ratos , Encéfalo , Microeletrodos , Técnicas Eletroquímicas
2.
Ying Yong Sheng Tai Xue Bao ; 35(3): 858-866, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38646774

RESUMO

Insect visual electrophysiological techniques are important to study the electrical characteristics of photoreceptor cells and visual neurons in insects, including electroretinography (ERG) and microelectrode intracellular recording (MIR). ERG records the changes of voltage or electric current in the retina of insects in response to different light stimuli, which occurs outside the cell. MIR records the changes in individual photoreceptor cells or visual neurons of an insect exposed to different lights, which occurs inside the cell. Insect visual electrophysiological techniques can explore the mechanism of electrophysiological response of insects' vision to light and reveal their sensitive light spectra and photoreceptor types. This review introduced the basic structure and the principle of ERG and MIR, and summarized their applications in insect researches in the past 20 years, which would provide references for elucidating the mechanism of light perception in insects and the use of insect phototropism to control pests.


Assuntos
Eletrorretinografia , Insetos , Células Fotorreceptoras de Invertebrados , Animais , Insetos/fisiologia , Eletrorretinografia/métodos , Células Fotorreceptoras de Invertebrados/fisiologia , Visão Ocular/fisiologia , Microeletrodos , Fenômenos Eletrofisiológicos , Eletrofisiologia/métodos
3.
J Vis Exp ; (205)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38526084

RESUMO

Large-scale neuronal networks and their complex distributed microcircuits are essential to generate perception, cognition, and behavior that emerge from patterns of spatiotemporal neuronal activity. These dynamic patterns emerging from functional groups of interconnected neuronal ensembles facilitate precise computations for processing and coding multiscale neural information, thereby driving higher brain functions. To probe the computational principles of neural dynamics underlying this complexity and investigate the multiscale impact of biological processes in health and disease, large-scale simultaneous recordings have become instrumental. Here, a high-density microelectrode array (HD-MEA) is employed to study two modalities of neural dynamics - hippocampal and olfactory bulb circuits from ex-vivo mouse brain slices and neuronal networks from in-vitro cell cultures of human induced pluripotent stem cells (iPSCs). The HD-MEA platform, with 4096 microelectrodes, enables non-invasive, multi-site, label-free recordings of extracellular firing patterns from thousands of neuronal ensembles simultaneously at high spatiotemporal resolution. This approach allows the characterization of several electrophysiological network-wide features, including single/-multi-unit spiking activity patterns and local field potential oscillations. To scrutinize these multidimensional neural data, we have developed several computational tools incorporating machine learning algorithms, automatic event detection and classification, graph theory, and other advanced analyses. By supplementing these computational pipelines with this platform, we provide a methodology for studying the large, multiscale, and multimodal dynamics from cell assemblies to networks. This can potentially advance our understanding of complex brain functions and cognitive processes in health and disease. Commitment to open science and insights into large-scale computational neural dynamics could enhance brain-inspired modeling, neuromorphic computing, and neural learning algorithms. Furthermore, understanding the underlying mechanisms of impaired large-scale neural computations and their interconnected microcircuit dynamics could lead to the identification of specific biomarkers, paving the way for more accurate diagnostic tools and targeted therapies for neurological disorders.


Assuntos
Células-Tronco Pluripotentes Induzidas , Camundongos , Animais , Humanos , Microeletrodos , Neurônios/fisiologia , Encéfalo/fisiologia , Fenômenos Eletrofisiológicos
4.
J Neural Eng ; 21(2)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38547529

RESUMO

Objective.Neuromodulation, particularly electrical stimulation, necessitates high spatial resolution to achieve artificial vision with high acuity. In epiretinal implants, this is hindered by the undesired activation of distal axons. Here, we investigate focal and axonal activation of retinal ganglion cells (RGCs) in epiretinal configuration for different sinusoidal stimulation frequencies.Approach.RGC responses to epiretinal sinusoidal stimulation at frequencies between 40 and 100 Hz were tested inex-vivophotoreceptor degenerated (rd10) isolated retinae. Experiments were conducted using a high-density CMOS-based microelectrode array, which allows to localize RGC cell bodies and axons at high spatial resolution.Main results.We report current and charge density thresholds for focal and distal axon activation at stimulation frequencies of 40, 60, 80, and 100 Hz for an electrode size with an effective area of 0.01 mm2. Activation of distal axons is avoided up to a stimulation amplitude of 0.23µA (corresponding to 17.3µC cm-2) at 40 Hz and up to a stimulation amplitude of 0.28µA (14.8µC cm-2) at 60 Hz. The threshold ratio between focal and axonal activation increases from 1.1 for 100 Hz up to 1.6 for 60 Hz, while at 40 Hz stimulation frequency, almost no axonal responses were detected in the tested intensity range. With the use of synaptic blockers, we demonstrate the underlying direct activation mechanism of the ganglion cells. Finally, using high-resolution electrical imaging and label-free electrophysiological axon tracking, we demonstrate the extent of activation in axon bundles.Significance.Our results can be exploited to define a spatially selective stimulation strategy avoiding axonal activation in future retinal implants, thereby solving one of the major limitations of artificial vision. The results may be extended to other fields of neuroprosthetics to achieve selective focal electrical stimulation.


Assuntos
Retina , Próteses Visuais , Retina/fisiologia , Células Ganglionares da Retina/fisiologia , Microeletrodos , Axônios/fisiologia , Estimulação Elétrica/métodos
5.
Anal Chem ; 96(14): 5719-5726, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38544485

RESUMO

Neuropathic pain is a chronic and severe syndrome for which effective therapy is insufficient and the release of ATP from microglia induced by sphingosine-1-phosphate (S1P) plays a vital role in neuropathic pain. Therefore, there is an urgent demand to develop highly sensitive and selective ATP biosensors for quantitative monitoring of low-concentration ATP in the complex nervous system, which helps in understanding the mechanism involved in neuropathic pain. Herein, we developed an electrochemical microsensor based on an entropy-driven bipedal DNA walker. First, the microsensor specifically recognized ATP via ATP aptamers, initiating the entropy-driven bipedal DNA walker. Subsequently, the bipedal DNA walker autonomously traversed the microelectrode interface, introducing methylene blue to the electrode surface and achieving cascade signal amplification. This microsensor showed excellent selectivity, stability, and a low limit of detection at 1.13 nM. The S1P-induced ATP release from BV2 cells was successfully monitored, and it was observed that dicumarol could inhibit this release, suggesting dicumarol as a potential treatment for neuropathic pain. The microsensor's small size exhibited significant potential for monitoring ATP level changes in neuropathic pain in vivo, which provides a new strategy for in situ and quantitative monitoring of nonelectroactive biomolecules associated with neurological diseases.


Assuntos
Técnicas Biossensoriais , Lisofosfolipídeos , Neuralgia , Esfingosina/análogos & derivados , Humanos , Entropia , Dicumarol , DNA/química , Microeletrodos , Trifosfato de Adenosina , Técnicas Eletroquímicas , Limite de Detecção
6.
Brain Behav Immun ; 118: 221-235, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38458498

RESUMO

The neuroinflammatory response to intracortical microelectrodes (IMEs) used with brain-machine interfacing (BMI) applications is regarded as the primary contributor to poor chronic performance. Recent developments in high-plex gene expression technologies have allowed for an evolution in the investigation of individual proteins or genes to be able to identify specific pathways of upregulated genes that may contribute to the neuroinflammatory response. Several key pathways that are upregulated following IME implantation are involved with the complement system. The complement system is part of the innate immune system involved in recognizing and eliminating pathogens - a significant contributor to the foreign body response against biomaterials. Specifically, we have identified Complement 3 (C3) as a gene of interest because it is the intersection of several key complement pathways. In this study, we investigated the role of C3 in the IME inflammatory response by comparing the neuroinflammatory gene expression at the microelectrode implant site between C3 knockout (C3-/-) and wild-type (WT) mice. We have found that, like in WT mice, implantation of intracortical microelectrodes in C3-/- mice yields a dramatic increase in the neuroinflammatory gene expression at all post-surgery time points investigated. However, compared to WT mice, C3 depletion showed reduced expression of many neuroinflammatory genes pre-surgery and 4 weeks post-surgery. Conversely, depletion of C3 increased the expression of many neuroinflammatory genes at 8 weeks and 16 weeks post-surgery, compared to WT mice. Our results suggest that C3 depletion may be a promising therapeutic target for acute, but not chronic, relief of the neuroinflammatory response to IME implantation. Additional compensatory targets may also be required for comprehensive long-term reduction of the neuroinflammatory response for improved intracortical microelectrode performance.


Assuntos
Complemento C3 , Inflamação , Animais , Camundongos , Complemento C3/genética , Eletrodos Implantados , Microeletrodos
7.
J Neural Eng ; 21(2)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38518365

RESUMO

Objective. Over the past decade, neural electrodes have played a crucial role in bridging biological tissues with electronic and robotic devices. This study focuses on evaluating the optimal tip profile and insertion speed for effectively implanting Paradromics' high-density fine microwire arrays (FµA) prototypes into the primary visual cortex (V1) of mice and rats, addressing the challenges associated with the 'bed-of-nails' effect and tissue dimpling.Approach. Tissue response was assessed by investigating the impact of electrodes on the blood-brain barrier (BBB) and cellular damage, with a specific emphasis on tailored insertion strategies to minimize tissue disruption during electrode implantation.Main results.Electro-sharpened arrays demonstrated a marked reduction in cellular damage within 50µm of the electrode tip compared to blunt and angled arrays. Histological analysis revealed that slow insertion speeds led to greater BBB compromise than fast and pneumatic methods. Successful single-unit recordings validated the efficacy of the optimized electro-sharpened arrays in capturing neural activity.Significance.These findings underscore the critical role of tailored insertion strategies in minimizing tissue damage during electrode implantation, highlighting the suitability of electro-sharpened arrays for long-term implant applications. This research contributes to a deeper understanding of the complexities associated with high-channel-count microelectrode array implantation, emphasizing the importance of meticulous assessment and optimization of key parameters for effective integration and minimal tissue disruption. By elucidating the interplay between insertion parameters and tissue response, our study lays a strong foundation for the development of advanced implantable devices with a reduction in reactive gliosis and improved performance in neural recording applications.


Assuntos
Barreira Hematoencefálica , Inflamação , Ratos , Animais , Eletrodos Implantados , Microeletrodos
8.
PLoS One ; 19(3): e0298320, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38483943

RESUMO

BACKGROUND: Deep Brain Stimulation (DBS), applying chronic electrical stimulation of subcortical structures, is a clinical intervention applied in major neurologic disorders. In order to achieve a good clinical effect, accurate electrode placement is necessary. The primary localisation is typically based on presurgical MRI imaging, often followed by intra-operative electrophysiology recording to increase the accuracy and to compensate for brain shift, especially in cases where the surgical target is small, and there is low contrast: e.g., in Parkinson's disease (PD) and in its common target, the subthalamic nucleus (STN). METHODS: We propose a novel, fully automatic method for intra-operative surgical navigation. First, the surgical target is segmented in presurgical MRI images using a statistical shape-intensity model. Next, automated alignment with intra-operatively recorded microelectrode recordings is performed using a probabilistic model of STN electrophysiology. We apply the method to a dataset of 120 PD patients with clinical T2 1.5T images, of which 48 also had available microelectrode recordings (MER). RESULTS: The proposed segmentation method achieved STN segmentation accuracy around dice = 0.60 compared to manual segmentation. This is comparable to the state-of-the-art on low-resolution clinical MRI data. When combined with electrophysiology-based alignment, we achieved an accuracy of 0.85 for correctly including recording sites of STN-labelled MERs in the final STN volume. CONCLUSION: The proposed method combines image-based segmentation of the subthalamic nucleus with microelectrode recordings to estimate their mutual location during the surgery in a fully automated process. Apart from its potential use in clinical targeting, the method can be used to map electrophysiological properties to specific parts of the basal ganglia structures and their vicinity.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Humanos , Doença de Parkinson/terapia , Doença de Parkinson/cirurgia , Estimulação Encefálica Profunda/métodos , Imageamento por Ressonância Magnética , Microeletrodos , Eletrofisiologia
9.
STAR Protoc ; 5(1): 102909, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38427565

RESUMO

Here, we present a protocol for the fabrication of transparent implantable electrode arrays for integrating optogenetics and electrophysiology. We describe steps for fabricating microelectrodes using the conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate). We then detail procedures for analyzing performance of the electrodes and recording light-evoked neural activities from the transgenic mouse. This protocol utilizes photolithography rather than conventional electrodeposition. For complete details on the use and execution of this protocol, please refer to Cho et al. (2022).1.


Assuntos
Optogenética , Roedores , Camundongos , Animais , Microeletrodos , Eletrodos Implantados , Camundongos Transgênicos , Eletrofisiologia/métodos
10.
Biosens Bioelectron ; 253: 116168, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38452571

RESUMO

Burst and local field potential (LFP) are fundamental components of brain activity, representing fast and slow rhythms, respectively. Understanding the intricate relationship between burst and LFP is crucial for deciphering the underlying mechanisms of brain dynamics. In this study, we fabricated high-performance microelectrode arrays (MEAs) using the SWCNTs/PEDOT:PSS nanocomposites, which exhibited favorable electrical properties (low impedance: 12.8 ± 2.44 kΩ) and minimal phase delay (-11.96 ± 1.64°). These MEAs enabled precise exploration of the burst-LFP interaction in cultured cortical networks. After a 14-day period of culture, we used the MEAs to monitor electrophysiological activities and revealed a time-locking relationship between burst and LFP, indicating the maturation of the neural network. To further investigate this relationship, we modulated burst firing patterns by treating the neural culture with increasing concentrations of glycine. The results indicated that glycine effectively altered burst firing patterns, with both duration and spike count increasing as the concentration rose. This was accompanied by an enhanced level of time-locking between burst and LFP but a decrease in synchrony among neurons. This study not only highlighted the pivotal role of SWCNTs/PEDOT:PSS-modified MEAs in elucidating the interaction between burst and LFP, bridging the gap between slow and fast brain rhythms in vitro but also provides valuable insights into the potential therapeutic strategies targeting neurological disorders associated with abnormal rhythm generation.


Assuntos
Técnicas Biossensoriais , Nanocompostos , Microeletrodos , Neurônios/fisiologia , Glicina
12.
Anal Chim Acta ; 1297: 342386, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38438231

RESUMO

In this work, we developed a new strategy to fabricate a series of transition metallic nanoparticles (NPs) embedded on B, N co-doped carbon nanotubes (CNTs) arrays modified flexible carbon fiber electrodes (M@BNCNTs/CF, M = Co, Fe, Ni) via facile inkjet printing assisted with chemical vapor deposition using Ionic liquid as solvent of printing ink and heteroatom dopants. Furthermore, Pt NPs via impregnation-thermal reduction process was anchored on the surface of Co@BNCNTs/CF (Pt-Co@BNCNTs/CF), which holds enhanced peroxidase-like activity and could be directly used as freestanding electrode to detect H2O2, exhibiting a low detection limit of 0.19 µM with wide linear range (0.5 µM-9.4 mM), and high sensitivity (1679 µA cm-2 mM-1). The excellent sensing performance of Pt-Co@BNCNTs/CF is attributed to the Pt, Co NPs anchored on CNTs with great catalytic activity, and the doping B, N would cause graphitic carbon with more defects to improve its inherent reactivity toward H2O2. Besides, CNTs arrays with high surface area also enlarge the exposure of active sites. Moreover, the Pt-Co@NBCNTs/CF microelectrode has been successfully applied in monitoring H2O2 secreted from human colonic cancer cells and normal colonic epithelial cells, which could offer crucial data for distinguishing various cell types and identifying cancer cells from normal cells. This work opens a new horizon to fabricate flexible miniaturized sensing device for extracellular analysis and offers an extended strategy to fabricate other metallic NPs embedded in heteroatoms doped CNTs functionalized flexible fiber electrode, by choosing diverse metal ions and ILs as inkjet printing precursors.


Assuntos
Nanotubos de Carbono , Humanos , Microeletrodos , Peróxido de Hidrogênio , Transporte Biológico , Peroxidases
13.
Proc Natl Acad Sci U S A ; 121(11): e2316365121, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38451949

RESUMO

Visceral signals are constantly processed by our central nervous system, enable homeostatic regulation, and influence perception, emotion, and cognition. While visceral processes at the cortical level have been extensively studied using non-invasive imaging techniques, very few studies have investigated how this information is processed at the single neuron level, both in humans and animals. Subcortical regions, relaying signals from peripheral interoceptors to cortical structures, are particularly understudied and how visceral information is processed in thalamic and subthalamic structures remains largely unknown. Here, we took advantage of intraoperative microelectrode recordings in patients undergoing surgery for deep brain stimulation (DBS) to investigate the activity of single neurons related to cardiac and respiratory functions in three subcortical regions: ventral intermedius nucleus (Vim) and ventral caudalis nucleus (Vc) of the thalamus, and subthalamic nucleus (STN). We report that the activity of a large portion of the recorded neurons (about 70%) was modulated by either the heartbeat, the cardiac inter-beat interval, or the respiration. These cardiac and respiratory response patterns varied largely across neurons both in terms of timing and their kind of modulation. A substantial proportion of these visceral neurons (30%) was responsive to more than one of the tested signals, underlining specialization and integration of cardiac and respiratory signals in STN and thalamic neurons. By extensively describing single unit activity related to cardiorespiratory function in thalamic and subthalamic neurons, our results highlight the major role of these subcortical regions in the processing of visceral signals.


Assuntos
Estimulação Encefálica Profunda , Núcleo Subtalâmico , Animais , Humanos , Tálamo/fisiologia , Neurônios/fisiologia , Microeletrodos
14.
J Neurosci Methods ; 404: 110077, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38336092

RESUMO

BACKGROUND: To study neural control of behavior, intracellular recording and stimulation of many neurons in freely moving animals would be ideal. However, current technologies limit the number of neurons that can be monitored and manipulated. A new technology has become available for intracellular recording and stimulation which we demonstrate in the tractable nervous system of Aplysia. NEW METHOD: Carbon fiber electrode arrays (whose tips are coated with platinum-iridium) were used with an in vitro feeding preparation to intracellularly record from and to control the activity of multiple neurons during feeding movements. RESULTS: In an in vitro feeding preparation, the carbon fiber electrode arrays recorded action potentials and subthreshold synaptic potentials during feeding movements. Depolarizing or hyperpolarizing currents activated or inhibited identified neurons (respectively), manipulating the movements of the feeding apparatus. COMPARISON WITH EXISTING METHOD(S): Standard glass microelectrodes that are commonly used for intracellular recording are stiff, liable to break in response to movement, and require many micromanipulators to be precisely positioned. In contrast, carbon fiber arrays are less sensitive to movement, but are capable of multiple channels of intracellular recording and stimulation. CONCLUSIONS: Carbon fiber arrays are a novel technology for intracellular recording that can be used in moving preparations. They can record both action potentials and synaptic activity in multiple neurons and can be used to stimulate multiple neurons in complex patterns.


Assuntos
Aplysia , Neurônios , Animais , Fibra de Carbono/química , Aplysia/fisiologia , Neurônios/fisiologia , Microeletrodos , Potenciais de Ação/fisiologia
15.
Mov Disord Clin Pract ; 11(4): 373-380, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38385792

RESUMO

BACKGROUND: Identifying the dorsolateral subthalamic nucleus (STN) for deep brain stimulation (DBS) in Parkinson's disease (PD) can be challenging due to the size and double-oblique orientation. Since 2015 we implemented 7-Tesla T2 weighted magnetic resonance imaging (7 T T2) for improving visualization and targeting of the dorsolateral STN. We describe the changes in surgical planning and outcome since implementation of 7 T T2 for DBS in PD. METHODS: By comparing two cohorts of STN DBS patients in different time periods we evaluated the influence of 7 T T2 on STN target planning, the number of microelectrode recording (MER) trajectories, length of STN activity and the postoperative motor (UPDRS) improvement. RESULTS: From February 2007 to January 2014, 1.5 and 3-Tesla T2 guided STN DBS with 3 MER channels was performed in 76 PD patients. Average length of recorded STN activity in the definite electrode trajectory was 3.9 ± 1.5 mm. From January 2015 to January 2022 7 T T2 and MER-guided STN DBS was performed in 182 PD patients. Average length of recorded STN activity in the definite electrode trajectory was 5.1 ± 1.3 mm and used MER channels decreased from 3 to 1. Average UPDRS improvement was comparable. CONCLUSION: Implementation of 7 T T2 for STN DBS enabled a refinement in targeting. Combining classical DBS targeting with dorsolateral STN alignment may be used to determine the optimal trajectory. The improvement in dorsolateral STN visualization can be used for further target refinements, for example adding probabilistic subthalamic connectivity, to enhance clinical outcome of STN DBS.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Núcleo Subtalâmico , Humanos , Doença de Parkinson/diagnóstico por imagem , Estimulação Encefálica Profunda/métodos , Núcleo Subtalâmico/diagnóstico por imagem , Imageamento por Ressonância Magnética , Microeletrodos
16.
Lab Chip ; 24(6): 1750-1761, 2024 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-38348692

RESUMO

Three-dimensional in vitro models in microfluidic systems are promising tools for studying cell biology, with complex models using multiple cell types combined with high resolution imaging. Neuronal models demand electrical readout of the activity of networks of single neurons, yet classical planar microelectrode arrays struggle to capture extracellular action potentials when neural soma are suspended distant from the microelectrodes. This study introduces sophisticated microfluidic microelectrode arrays, specifically tailored for electrophysiology of 3D neuronal cultures. Using multilayer photolithography of permanent epoxy photoresists, we developed devices having 12 independent culture modules in a convenient format. Each module has two adjacent compartments for hydrogel-based 3D cell culture, with tunnels allowing projection of neurites between compartments. Microelectrodes integrated in the tunnels record action potentials as they pass between the compartments. Mesh ceilings separate the compartments from overlying wells, allowing for simple cell seeding and later nutrient, gas and waste exchange and application of test substances. Using these devices, we have demonstrated 3D neuronal culture, including electrophysiological recording and live imaging. This microphysiological platform will enable high-throughput investigation of neuronal networks for investigation of neurological disorders, neural pharmacology and basic neuroscience. Further models could include cocultures representing multiple brain regions or innervation models of other organs.


Assuntos
Sistemas Microfisiológicos , Neurônios , Potenciais de Ação/fisiologia , Técnicas de Cocultura , Técnicas de Cultura de Células em Três Dimensões , Microeletrodos
17.
Biomed Microdevices ; 26(1): 17, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345721

RESUMO

Utilising a flexible intracortical microprobe to record/stimulate neurons minimises the incompatibility between the implanted microprobe and the brain, reducing tissue damage due to the brain micromotion. Applying bio-dissolvable coating materials temporarily makes a flexible microprobe stiff to tolerate the penetration force during insertion. However, the inability to adjust the dissolving time after the microprobe contact with the cerebrospinal fluid may lead to inaccuracy in the microprobe positioning. Furthermore, since the dissolving process is irreversible, any subsequent positioning error cannot be corrected by re-stiffening the microprobe. The purpose of this study is to propose an intracortical microprobe that incorporates two compressible structures to make the microprobe both adaptive to the brain during operation and stiff during insertion. Applying a compressive force by an inserter compresses the two compressible structures completely, resulting in increasing the equivalent elastic modulus. Thus, instant switching between stiff and soft modes can be accomplished as many times as necessary to ensure high-accuracy positioning while causing minimal tissue damage. The equivalent elastic modulus of the microprobe during operation is ≈ 23 kPa, which is ≈ 42% less than the existing counterpart, resulting in ≈ 46% less maximum strain generated on the surrounding tissue under brain longitudinal motion. The self-stiffening microprobe and surrounding neural tissue are simulated during insertion and operation to confirm the efficiency of the design. Two-photon polymerisation technology is utilised to 3D print the proposed microprobe, which is experimentally validated and inserted into a lamb's brain without buckling.


Assuntos
Encéfalo , Fenômenos Mecânicos , Animais , Ovinos , Microeletrodos , Módulo de Elasticidade , Pressão , Encéfalo/fisiologia
18.
Sci Rep ; 14(1): 3729, 2024 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-38355737

RESUMO

Electrodes with nanostructured surface have emerged as promising low-impedance neural interfaces that can avoid the charge-injection restrictions typically associated to microelectrodes. In this work, we propose a novel approximation, based on a two-step template assisted electrodeposition technique, to obtain flexible nanostructured electrodes coated with core-shell Ni-Au vertical nanowires. These nanowires benefit from biocompatibility of the Au shell exposed to the environment and the mechanical properties of Ni that allow for nanowires longer and more homogeneous in length than their only-Au counterparts. The nanostructured electrodes show impedance values, measured by electrochemical impedance spectroscopy (EIS), at least 9 times lower than those of flat reference electrodes. This ratio is in good accordance with the increased effective surface area determined both from SEM images and cyclic voltammetry measurements, evidencing that only Au is exposed to the medium. The observed EIS profile evolution of Ni-Au electrodes over 7 days were very close to those of Au electrodes and differently from Ni ones. Finally, the morphology, viability and neuronal differentiation of rat embryonic cortical cells cultured on Ni-Au NW electrodes were found to be similar to those on control (glass) substrates and Au NW electrodes, accompanied by a lower glial cell differentiation. This positive in-vitro neural cell behavior encourages further investigation to explore the tissue responses that the implantation of these nanostructured electrodes might elicit in healthy (damaged) neural tissues in vivo, with special emphasis on eventual tissue encapsulation.


Assuntos
Nanoestruturas , Nanofios , Ratos , Animais , Eletrodos , Microeletrodos , Neurônios/fisiologia , Impedância Elétrica
19.
ACS Chem Neurosci ; 15(4): 772-782, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38301116

RESUMO

Free, ionic zinc (Zn2+) modulates neurotransmitter dynamics in the brain. However, the sub-s effects of transient concentration changes of Zn2+ on neurotransmitter release and uptake are not well understood. To address this lack of knowledge, we have combined the photolysis of the novel caged Zn2+ compound [Zn(DPAdeCageOMe)]+ with fast scan cyclic voltammetry (FSCV) at carbon fiber microelectrodes in live, whole brain preparations from zebrafish (Danio rerio). After treating the brain with [Zn(DPAdeCageOMe)]+, Zn2+ was released by application of light that was gated through a computer-controlled shutter synchronized with the FSCV measurements and delivered through a 1 mm fiber optic cable. We systematically optimized the photocage concentration and light application parameters, including the total duration and light-to-electrical stimulation delay time. While sub-s Zn2+ application with this method inhibited DA reuptake, assessed by the first-order rate constant (k) and half-life (t1/2), it had no effect on the electrically stimulated DA overflow ([DA]STIM). Increasing the photocage concentration and light duration progressively inhibited uptake, with maximal effects occurring at 100 µM and 800 ms, respectively. Furthermore, uptake was inhibited 200 ms after Zn2+ photorelease, but no measurable effect occurred after 800 ms. We expect that application of this method to the zebrafish whole brain and other preparations will help expand the current knowledge of how Zn2+ affects neurotransmitter release/uptake in select neurological disease states.


Assuntos
Dopamina , Peixe-Zebra , Animais , Dopamina/farmacologia , Fotólise , Encéfalo , Neurotransmissores , Estimulação Elétrica , Microeletrodos
20.
Analyst ; 149(8): 2351-2362, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38375597

RESUMO

Monitoring the coordinated signaling of dopamine (DA) and serotonin (5-HT) is important for advancing our understanding of the brain. However, the co-detection and robust quantification of these signals at low concentrations is yet to be demonstrated. Here, we present the quantification of DA and 5-HT using nano-graphitic (NG) sensors together with fast-scan cyclic voltammetry (FSCV) employing an engineered N-shape potential waveform. Our method yields 6% error in quantifying DA and 5-HT analytes present in in vitro mixtures at concentrations below 100 nM. This advance is due to the electrochemical properties of NG sensors which, in combination with the engineered FSCV waveform, provided distinguishable cyclic voltammograms (CVs) for DA and 5-HT. We also demonstrate the generalizability of the prediction model across different NG sensors, which arises from the consistent voltammetric fingerprints produced by our NG sensors. Curiously, the proposed engineered waveform also improves the distinguishability of DA and 5-HT CVs obtained from traditional carbon fiber (CF) microelectrodes. Nevertheless, this improved distinguishability of CVs obtained from CF is inferior to that of NG sensors, arising from differences in the electrochemical properties of the sensor materials. Our findings demonstrate the potential of NG sensors and our proposed FSCV waveform for future brain studies.


Assuntos
Dopamina , Grafite , Carbono , Serotonina , Fibra de Carbono , Microeletrodos , Técnicas Eletroquímicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...